電氣規(guī)格: (23℃±5℃)
交流瓦特
(50或60Hz, PF功率因素0.6到1, CT比流器比值=1, 電壓> 交流4V, 電流 >交流mA檔位中的1mA,
電流> 交流A檔位中的0.04A, 規(guī)格適用于連續(xù)波形)
檔位 ( 0 ~ 30A) | 分辨率 | 讀值誤差 |
0.050 – 9.999 W | 0.001W | ±2% ± 0.025W |
10.00 – 99.99 W | 0.01W | ±2% ± 0.25W |
100.0 - 999.9 W | 0.1W | ±2% ± 2.5W |
1.000 – 9.999 KW | 0.001 KW | ±2% ± 0.025KW |
10.00 – 99.99 KW | 0.01 KW | ±2% ± 0.25KW |
100.0 – 999.9 KW | 0.1 KW | ±2% ± 2.5KW |
1000 – 9999 KW | 1 KW | ±2% ± 25KW |
檔位 (30 ~ 50A) | 分辨率 | 讀值誤差 |
0.050 – 9.999 W | 0.001W | ±2% of VA ± 5dgts |
10.00 – 99.99 W | 0.01W | ±2% of VA ± 5dgts |
100.0 - 999.9 W | 0.1W | ±2% of VA ± 5dgts |
1.000 – 9.999 KW | 0.001 KW | ±2% of VA ± 5dgts |
10.00 – 99.99 KW | 0.01 KW | ±2% of VA± 5dgts |
100.0 – 999.9 KW | 0.1 KW | ±2% of VA ± 5dgts |
1000 – 9999 KW | 1 KW | ±2% of VA ± 5dgts |
CT 比流器比值的檔位: 1 到 250
H.P. (馬力) H.P. = W / 746
交流視在功率 (VA, 從0.000VA 到 9999 KVA): VA = V r.m.s. x A r.m.s
交流虛功率 (VAR, 從0.000VAR 到 9999 KVAR): VAR = √(VA² – W²)
交流實(shí)功率 (mWH, WH 或 KWH, 從 0Mwh 到 999,999 KWH):
WH = W * Time (in hours)
交流電壓
(自動(dòng)換檔, 均方根值, 波峰因素<4, 輸入阻抗10MΩ, 峰值為860VDC, AC交流電800V過(guò)載保護(hù))
檔位 | 分辨率 | 讀值誤差 (50/60Hz) |
5V – 250 V | 0.1 V | ±0.5% ± 5dgts |
250 V – 600 V | 0.1 V | ±0.5% ± 5dgts |
交流電流 (自動(dòng)檔位, 均方根值, 波峰因素< 4, 當(dāng)CT=1, mA檔位的峰值為880mADC以內(nèi),
A檔位的峰值為73.5ADC以內(nèi), AC交流電600A過(guò)載保護(hù))
檔位 | 分辨率 | 讀值誤差 (50/60Hz) |
0.5 – 60mA | 0.01mA | ±0.5% ± 5dgts |
60 – 100mA | 0.01mA | ±0.5% ± 50dgts |
100 – 600 mA | 0.1 mA | ±0.5% ± 5dgts |
0.05 – 3 A | 0.001 A | ±0.5% ± 5dgts |
3 – 30 A | 0.01 A | ±0.5% ± 5dgts |
30 – 50 A | 0.01 A | ±1.0% ± 5dgts |
功率因素
(PF, 交流電壓>4V, 交流mA > 1mA, 交流A > 0.04A, 瓦特> 50位讀值)
檔位 | 分辨率 | 準(zhǔn)確率 |
0.000 – 1.000 | 0.001 | ±0.04 |